Single Mode Fiber G.657.B3
Fiber type    G.657.B3
OPK code    B3
Rev. 013-20/26
| 
			 Fiber type  | 
			
			 G.657.B3  | 
		
| 
			 OPK code  | 
			
			 B3  | 
		
| 
			 Core  | 
			
			 Germanium doped silica  | 
		
| 
			 Cladding  | 
			
			 Silica, step index and matched clad type  | 
		
| 
			 Coating  | 
			
			 Dual layers of UV-cured acrylate  | 
		
| 
			 
  | 
			
			 
  | 
		
| 
			 Optical Characteristics  | 
			
			 
  | 
		
| 
			 Attenuation coefficient Tight Buffered Cables (typical / max.)  | 
			
			 
  | 
		
| 
			 at 1310 nm  | 
			
			 0.35 / 0.40 dB/km  | 
		
| 
			 at 1550 nm  | 
			
			 0.25 / 0.40 dB/km  | 
		
| 
			 Point of discontinuity at 1310 nm and 1550 nm  | 
			
			 ≤ 0.1 dB  | 
		
| 
			 Cable cut-off wavelength (λcc)  | 
			
			 ≤ 1260 nm  | 
		
| 
			 Zero dispersion wavelength  | 
			
			 1300 – 1324 nm  | 
		
| 
			 Zero dispersion slope  | 
			
			 ≤ 0.092 (ps/(nm2/km )  | 
		
| 
			 Chromatic dispersion at 1285 ~ 1330 nm  | 
			
			 ≤ 3.5 ps/(nm.km)  | 
		
| 
			 Chromatic dispersion at 1550 nm  | 
			
			 ≤ 18.0 ps/(nm.km)  | 
		
| 
			 Maximum individual fiber PMD  | 
			
			 ≤ 0.15 ps/Ökm  | 
		
| 
			 Fiber PMD link value  | 
			
			 ≤ 0.1 ps/Ökm  | 
		
| 
			 Effective group index of refraction at 1310 nm  | 
			
			 1.467  | 
		
| 
			 Effective group index of refraction at 1550 nm  | 
			
			 1.468  | 
		
| 
			 Backscatter coefficient at 1310 nm  | 
			
			 -79.2 dB  | 
		
| 
			 Backscatter coefficient at 1550 nm  | 
			
			 -81.7 dB  | 
		
| 
			 
  | 
			
			 
  | 
		
| 
			 Geometrical Characteristics  | 
			
			 
  | 
		
| 
			 Mode field diameter at 1310 nm  | 
			
			 8.4 ± 0.4 µm  | 
		
| 
			 Core/Cladding concentricity error  | 
			
			 ≤ 0.5 µm  | 
		
| 
			 Cladding diameter  | 
			
			 125.0 ± 0.7 µm  | 
		
| 
			 Cladding non-circularity  | 
			
			 ≤ 0.7%  | 
		
| 
			 Primary coating diameter (uncoloured fibre)  | 
			
			 242 ±5 µm  | 
		
| 
			 Primary coating diameter (coloured fibre)  | 
			
			 250 ±10 µm  | 
		
| 
			 Fibre curl radius  | 
			
			 ≥ 4.0 m  | 
		
| 
			 Coating-Cladding concentricity  | 
			
			 ≤ 12 µm  | 
		
| 
			 
  | 
			
			 
  | 
		
| 
			 Macrobending loss  | 
			
			 
  | 
		
| 
			 1 turn, mandrel radius 10 mm at 1550 nm  | 
			
			 ≤ 0.03 dB  | 
		
| 
			 1 turn, mandrel radius 10 mm at 1625 nm  | 
			
			 ≤ 0.1 dB  | 
		
| 
			 1 turn, mandrel radius 7.5 mm at 1550 nm  | 
			
			 ≤ 0.08 dB  | 
		
| 
			 1 turn, mandrel radius 7.5 mm at 1625 nm  | 
			
			 ≤ 0.25 dB  | 
		
| 
			 1 turn, mandrel radius 5 mm at 1550 nm  | 
			
			 ≤ 0.15 dB  | 
		
| 
			 1 turn, mandrel radius 5 mm at 1625 nm  | 
			
			 ≤ 0.45 dB  | 
		
| 
			 
  | 
			
			 
  | 
		
| 
			 Mechanical Characteristics  | 
			
			 
  | 
		
| 
			 Coating strip force  | 
			
			 1.3 ~ 8.9 N  | 
		
| 
			 
  | 
			
			 
  | 
		
| 
			 Typical attenuation is the value measured for at least 90% of the fibers in the cable. OTDR measurement values can only be guaranteed for cable lengths of 1000 m and more. Cable on the reel may show an discontinuity of the OTDR curve caused by winding of the cable on the reel.  | 
		|