Highly Durable Hybrid Cable
Highly Durable Hybrid Cable 
Rev. 0201-23/03
Highly durable flexible cable for applications where there is a requirement for data communication by fiber optic and at the same time is needed power supply. Suitable for FTTA applications, CCTV systems or for connections of movable equipment.
 
| 
			 Fibre count  | 
			
			 2  | 
		
| 
			 Fibre Type  | 
			
			 G.657.A1, G.657.A2  | 
		
| 
			 Fibre colour  | 
			
			 Natural  | 
		
| 
			 Buffer diameter  | 
			
			 0.9 mm  | 
		
| 
			 Buffer material  | 
			
			 UV curable acrylate  | 
		
| 
			 Buffer colour  | 
			
			 Blue  | 
		
| 
			 Simplex Colour  | 
			
			 Yellow (identified by numbers #1 a #2)  | 
		
| 
			 Simplex jacket  | 
			
			 Halogen-free flame-retardant thermoplastic compound  | 
		
| 
			 Simplex diameter  | 
			
			 1.8 mm  | 
		
| 
			 Conductor count  | 
			
			 3  | 
		
| 
			 Conductor  | 
			
			 Stranded Tinned Copper, AWG 16 (19x0.3 mm)  | 
		
| 
			 Wire Insulation material  | 
			
			 FEP  | 
		
| 
			 Wire Insulation colour  | 
			
			 White, Black, Red  | 
		
| 
			 Wire Insulation diameter  | 
			
			 1.9 mm  | 
		
| 
			 Core wrapping  | 
			
			 Water-swellable tape  | 
		
| 
			 Strength members  | 
			
			 Water-swellable Aramid yarns  | 
		
| 
			 Inner jacket  | 
			
			 Flame-retardant TPU Outer Jacket (V-2 acc. to UL94)  | 
		
| 
			 Inner jacket thickness  | 
			
			 0.8 mm  | 
		
| 
			 Peripheral strength members Water-swellable glass yarns  | 
			
			 
  | 
		
| 
			 Outer jacket  | 
			
			 UV stable Flame-retardant TPU Outer Jacket (V-2 acc. to UL94)  | 
		
| 
			 Outer jacket thickness  | 
			
			 1.3 mm  | 
		
| 
			 Cable outer diameter  | 
			
			 11.7 mm  | 
			
			 
  | 
		
| 
			 Max. Loading (Short Term)  | 
			
			 8000 N  | 
			
			 EN 60794-1-21-E1  | 
		
| 
			 Max. Loading (Long Term)  | 
			
			 3500 N  | 
			
			 EN 60794-1-21-E1  | 
		
| 
			 Abrasion  | 
			
			 5N/10 000 cycles  | 
			
			 EN 60794-1-21-E2  | 
		
| 
			 Max. compressive loading  | 
			
			 5500 N/10cm]  | 
			
			 EN 60794-1-21-E3  | 
		
| 
			 Max. Impact loading  | 
			
			 27 Nm  | 
			
			 EN 60794-1-21-E4  | 
		
| 
			 Kink  | 
			
			 150 mm  | 
			
			 EN 60794-1-21-E10  | 
		
| 
			 Min. bend radius not load  | 
			
			 75 mm  | 
			
			 EN 60794-1-21-E11  | 
		
| 
			 Min. bend radius load  | 
			
			 150 mm  | 
			
			 EN 60794-1-21-E11  | 
		
| 
			 Torsion resistence  | 
			
			 ±360°  | 
			
			 EN 60794-1-21-E7  | 
		
| 
			 Wire resistance  | 
			
			 14.6 Ohm/km at 20°C  | 
			
			 
  | 
		
| 
			 Wire Insulation Spark Test 3000V/0.15 sec.  | 
			
			 Pass  | 
			
			 
  | 
		
| 
			 Test voltage underwater 2000V/ 1 hour (room temp.)  | 
			
			 Pass  | 
			
			 
  | 
		
| 
			 Operating temperature range (static)  | 
			
			 -40 až +70°C  | 
			
			 EN 60794-1-22-F1  | 
		
| 
			 Operating temperature range (dynamic)  | 
			
			 -10 až +70°C  | 
			
			 EN 60794-1-22-F1  | 
		
| 
			 Storage temperature range  | 
			
			 -40 až +70°C  | 
			
			 EN 60794-1-22-F1  | 
		
| 
			 Freezing test  | 
			
			 Pass  | 
			
			 IEC 60794-1-22-F15  | 
		
| 
			 Aging test  | 
			
			 Pass  | 
			
			 IEC 60794-1-22-F9  | 
		
| 
			 Water tightness  | 
			
			 Pass  | 
			
			 EN 60794-1-22-F5  | 
		
| 
			 Cable Weight (calc.)  | 
			
			 66 kg/km  | 
			
			 
  | 
		
| 
			 Class of fire reaction  | 
			
			 Fca  | 
			
			 EN 13501-6  | 
		
| 
			 Static coefficient of friction (stainless steel - dry)  | 
			
			 0.73  | 
			
			 
  | 
		
OPK-U-SPC-2(5×1,8)A9AEUGU-xx-BK
xx – fiber type (see Cable code datasheet) 
Print legend: Manufacturer –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length            2100 m±5% on plywood reel or solid wooden non-returnable drum