Indoor-Outdoor CST Armoured Multi-tube Cable 48F (HC)
                    
                Indoor/Outdoor CST Armoured Multi-tube Cable 48F (HC)
Rev. 0062-20/32
Fibre optic cable with full protection against rodents for direct burial installation.
| 
			 Fiber count  | 
			
			 48  | 
		
| 
			 Fiber Type  | 
			
			 G.652.D, G.657.A1, G.657.A2, G.655, G.656, OM1, OM2, OM3, OM4  | 
		
| 
			 Fiber color  | 
			
			 Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua  | 
		
| 
			 Tube  | 
			
			 Gel-Filled PBT buffer tube  | 
		
| 
			 Tube color  | 
			
			 Blue, Orange, Green, Brown  | 
		
| 
			 Tube filling compound  | 
			
			 Thixotropic Jelly Compound  | 
		
| 
			 Central strength member  | 
			
			 FRP rod  | 
		
| 
			 Core wrapping  | 
			
			 Water-swellable tape  | 
		
| 
			 Peripheral strength members  | 
			
			 Water-swellable glass yarns  | 
		
| 
			 Armouring  | 
			
			 Corrugated steel tape, longitudinally under jacket  | 
		
| 
			 Outer jacket  | 
			
			 UV resistant Thermoplastic FR-LSHF compound according to BS 7878:7  | 
		
| 
			 Outer jacket thickness  | 
			
			 1.5 mm  | 
		
| 
			 Cable outer diameter  | 
			
			 11.4  | 
			
			 [mm]  | 
		
| 
			 Tube count  | 
			
			 
  | 
			
			 4  | 
		
| 
			 Filler count  | 
			
			 
  | 
			
			 1  | 
		
| 
			 Max. Loading (Short Term)  | 
			
			 1800  | 
			
			 [N]  | 
		
| 
			 Max. Loading (Long Term)  | 
			
			 480  | 
			
			 [N]  | 
		
| 
			 Max. compressive loading  | 
			
			 3500  | 
			
			 [N]  | 
		
| 
			 Max. Impact loading  | 
			
			 25  | 
			
			 [Nm]  | 
		
| 
			 Min. bend radius not load  | 
			
			 15  | 
			
			 [OD]  | 
		
| 
			 Min. bend radius load  | 
			
			 20  | 
			
			 [OD]  | 
		
| 
			 Operating temperature range  | 
			
			 -40 to +70  | 
			
			 [°C]  | 
		
| 
			 Storage temperature range  | 
			
			 -40 to +70  | 
			
			 [°C]  | 
		
| 
			 Installation temperature range  | 
			
			 -15 to +50  | 
			
			 [°C]  | 
		
| 
			 Cable Weight (calc.)  | 
			
			 156  | 
			
			 [kg/km]  | 
		
| 
			 Class of fire reaction  | 
			
			 Fca  | 
			
			 
  | 
		
| 
			 Test standards: EN 60793-1, EN 60794-1-21, EN 60794-1-22, EN 13501-6  | 
		||
OPK-U-MTFDS-48(5x2.3)LTGXH-xx-BK
xx – fiber type (see Cable code datasheet)
| Marking Method: | Ink-Jet | 
| Print legend: | OPK –cable type – lot number- length marking per 1 m (customer print legend available on request) | 
| Delivery length: | 2000 m, 4000 m ±5% on plywood reel or solid wooden non-returnable drum |