Outdoor Multi-tube Micro Cable 144F (RD)
                    
                Outdoor Multi-tube Micro Cable 144F (RD)
Rev. 0276-22/27
Cable for external installation by air-blowing technique
| 
			 Fiber Type  | 
			
			 G.657.A1 200µm  | 
		
| 
			 Fiber color  | 
			
			 Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua  | 
		
| 
			 Tube  | 
			
			 Gel-Filled PBT buffer tube  | 
		
| 
			 Tube color in inner layer  | 
			
			 Blue, Orange, Green  | 
		
| 
			 Tube color in outer layer  | 
			
			 Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua  | 
		
| 
			 Tube filling compound  | 
			
			 Thixotropic Jelly Compound  | 
		
| 
			 Strength member  | 
			
			 FRP rods  | 
		
| 
			 Ripcord  | 
			
			 1x under outer jacket  | 
		
| 
			 Outer jacket  | 
			
			 PA12 Orange  | 
		
| 
			 Outer jacket thickness  | 
			
			 0.4 mm  | 
		
| 
			 Cable outer diameter  | 
			
			 5.9  | 
			
			 [mm]  | 
			
			 
  | 
		
| 
			 Tube count  | 
			
			 12  | 
			
			 
  | 
			
			 
  | 
		
| 
			 Filler count  | 
			
			 0  | 
			
			 
  | 
			
			 
  | 
		
| 
			 Max. Loading (Short Term)  | 
			
			 220  | 
			
			 [N]  | 
			
			 EN 60794-1-21-E1  | 
		
| 
			 Max. Loading (Long Term)  | 
			
			 50  | 
			
			 [N]  | 
			
			 EN 60794-1-21-E1  | 
		
| 
			 Max. compressive loading  | 
			
			 200  | 
			
			 [N/10cm]  | 
			
			 EN 60794-1-21-E3  | 
		
| 
			 Max. Impact loading  | 
			
			 2  | 
			
			 [Nm]  | 
			
			 EN 60794-1-21-E4  | 
		
| 
			 Min. bend radius not load  | 
			
			 85  | 
			
			 [mm]  | 
			
			 EN 60794-1-21-E11  | 
		
| 
			 Min. bend radius load  | 
			
			 150  | 
			
			 [mm]  | 
			
			 EN 60794-1-21-E11  | 
		
| 
			 Operating temperature range  | 
			
			 -30 to +70  | 
			
			 [°C]  | 
			
			 EN 60794-1-22-F1  | 
		
| 
			 Storage temperature range  | 
			
			 -40 to +70  | 
			
			 [°C]  | 
			
			 EN 60794-1-22-F1  | 
		
| 
			 Installation temperature range  | 
			
			 -10 to +50  | 
			
			 [°C]  | 
			
			 EN 60794-1-22-F1  | 
		
| 
			 Water tightness  | 
			
			 No water detected on free end  | 
			
			 
  | 
			
			 EN 60794-1-22-F5  | 
		
| 
			 Cable Weight (calc.)  | 
			
			 30  | 
			
			 [kg/km]  | 
			
			 
  | 
		
| 
			 Class of fire reaction  | 
			
			 Fca  | 
			
			 
  | 
			
			 EN 13501-6  | 
		
Attenuation @Wavelength            1310 / 1550 / 1625    [nm]
Typical Attenuation            0.33 / 0.23 / 0.24    [dB/km] 
Maximum Attenuation            0.38 / 0.26 / 0.28     [dB/km]
Typical attenuation is the value measured for at least 90% of the fibers in the cable. 
OPK-O-MTFDM-144(12x1.2)LTN-200A1-OG
Print legend                OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length            2100 m, 4200 m ±5% on plywood reel