OPTOKON

Master FC Patchcord

Master FC Patchcord

We offer an extensive range of pre-terminated cable assemblies that are 100% tested to ensure conformance with your specifications.  These assemblies are used for measuring and manufacturing of fiber optic components and optical network testing.

The Master patchcord is equipped with a Master connector according to the specifications below. The master connector is marked and specified with its Serial Number, which ensures traceability of transmission and geometrical parameters. The second connector is a standard type. For the hybrid patchcord version different types of master and standard connector types are also available.

 

 

Insertion loss2 (IL) 
(IEC 61300-3-4)

SM Ultra PC

SM Angle PC

0.10 dB max

0.10 dB max

Return loss2 (RL)
(IEC 61300-3-6, method 1)

≥ 55 dB1

≥ 70 dB1

PDL2

max 0.1 dB

Strain relief

max 100 N

Allowable input power

max 1.0 W

Strain relief

100 N

Operating temperature

-30°C to +70°C

Durability

min 1000 cycles

Assembly procedure

glue and polish

Connection

physical contact

Lock mechanism

coupling nut

Standards

JIS 5970, EIA/TIA FOCIS, IEC 61754-13, EN 50377-2, GR-326-CORE

Ferrule material

full ceramic zirconia

Connector material

zinc alloy, nickel plated

Adapter material

zinc alloy, nickel plated, zirconia sleeve

Connector lifetime

20 years in environment defined by EN 61753-1:2007, category C

Geometrical parameters: 

Eccentricity of core for the center of ferrule

≤ 0.5 µm

Outer diameter of ferrule

2.5 mm connectors:               2.499 µm

SFF connectors:                     1.249 µm

End curve offset

                                               ≤25 µm

Fiber height

                                               -30 to +50 nm

End curve radius: 2.5 mm connectors:

                            SFF connectors:

PC polishing: 10 – 18 mm       APC polishing: 5 – 12 mm

PC/APC:        5 – 12 mm

APC angle

8 ± 0.1°

Features: 

  • ISO 9100 approved
  • 100% Return loss test
  • 100% Visual Inspection
  • 100% Insertion loss test
  • 100% Interferometric test
  • Manufactured to meet IEC/EN Standards
  • Batch tracebility

          

 

Visual inspection:

Single mode

Allowable Defects and Scratches

 

Zone

Description

Diameter

Defects (diameter)

Scratches (width)

1a

Core Zone

0 to 25 μm

none

none

1b

Cladding Zone

25 to 120 μm

any < 2 μm
5 from 2 - 5 μm
none > 5 μm

none > 3 μm

-

Adhesive Zone

120 to 130 μm

any

any

2

Contact Zone

130 to 250 μm

none > 10 μm

any

Single mode:
IEC 61300-3-4, Insertion method (C2)
   

 

M

-

YYY

/

AAA

-

20XXX

-

 (LLL4)

/02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 YYY – Master Connector

 

 

 

 20 - cable Ø 2.0 mm

 

 

AAA3 – Second Connector

 

 

 

 XXX - type of fiber

 

 

Type

Description

 

 

 

S2D

SM 9/125 µm (G.652D)

 

 

 UPC

FC/UPC

 

 

 

S7A1

SM 9/125 µm (G.657A1)

 

 

 NPC

FC/APC

 

 

 

 

 

Note:     1) RL ≥ 58 dB (UPC) and RL ≥ 78 dB (APC) measured with low coherence reflectometry (IEC 61300-3-6 method 3 OLCR)
              2) Valid over 1260-1650 nm wavelength range and within operation temperature range -30 to +70°C, tested according to IEC 61300-3-12
              3) AAA – second connector types according to relevant datasheets
              4) Standard Master patchcord length – 2 m, other on demand