Highly durable flexible cable for applications where there is a requirement for data communication by fiber optic and at the same time is needed power supply. Suitable for FTTA applications, CCTV systems or for connections of movable equipment.

Fibre count

2

Fibre Type

G.657.A1, G.657.A2

Fibre colour

Natural

Buffer diameter

0.9 mm

Buffer material

UV curable acrylate

Buffer colour

Blue

Simplex Colour

Yellow (identified by numbers #1 a #2)

Simplex jacket

Thermoplastic FR-LSHF compound according to BS 7878:7  and  DIN VDE 0207, part 24, type HM2

Simplex diameter

1.8 mm

Wire count

3

Wire

Stranded Tinned Copper, AWG 16 (19x0.3 mm)

Wire Insulation material

FEP

Wire Insulation colour

White, Black, Red

Wire Insulation diameter

1.9 mm

Core wrapping

Water-swellable tape

Strength members

Water-swellable Aramid yarns

Inner jacket

Flame-retardant TPU Outer Jacket (V-2 acc. to UL94)

Inner jacket thickness

0.8 mm

Peripheral strength members

Water-swellable glass yarns

Outer jacket

UV stable Flame-retardant TPU Outer Jacket (V-2 acc. to UL94)

Outer jacket thickness

1.3 mm

 

Cable outer diameter

11.7

[mm]

 

Max. Loading (Short Term)

8000

[N]

EN 60794-1-21-E1

Max. Loading (Long Term)

3500

[N]

EN 60794-1-21-E1

Abrasion

5N/10 000 cycles

 

EN 60794-1-21-E2

Max. compressive loading

3000

[N/10cm]

EN 60794-1-21-E3

Max. Impact loading

20

[Nm ]

EN 60794-1-21-E4

Kink

150

[mm]

EN 60794-1-21-E10

Min. bend radius not load

75

[mm]

EN 60794-1-21-E11

Min. bend radius load

150

[mm]

EN 60794-1-21-E11

Wire resistance

14.6

[Ohm/km at 20°C]

 

Wire Insulation Spark Test 3000V/0.15 sec.

Pass

 

 

Test voltage 2000V underwater 1 hour at the room temp.

Pass

 

 

Operating temperature range (static)

-40 až +70

[°C]

EN 60794-1-22-F1

Operating temperature range (dynamic)

-10 až +70

[°C]

EN 60794-1-22-F1

Storage temperature range

-40 až +70

[°C]

EN 60794-1-22-F1

Freezing test

Pass

 

IEC 60794-1-22-F15

Aging test

Pass

 

IEC 60794-1-22-F9

Cable Weight (calc.)

66

[kg/km]

 

Class of fire reaction

Fca

 

EN 13501-6

Static coefficient of friction (stainless steel - dry)

0.73

 

 

 

OPK-U-SPC-2(5×1,8)A9AEUGU-xx-BK
xx – fiber type (see Cable code datasheet) 

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2000 m ± 5% on plywood reel or solid wooden non-returnable drum