Indoor/Outdoor fiber optic cable for installing into ducts or on grids.

Fibre count

up to 12

Fibre Type

G.652.D, G.657.A1, G.657.A2, G.655, OM1, OM2, OM2+, OM3, OM4, OM5

Fibre colour

Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua

Tube

Gel-Filled PBT buffer tube

Tube colour

Natural / White

Filling compound

Thixotropic Jelly Compound

Peripheral strength members

Water-swellable Glass yarn

Ripcord

1x under outer jacket

Outer jacket

UV resistant Thermoplastic FR-LSHF compound according to BS 7878:7 
and  DIN VDE 0207, part 24, type HM2

Outer jacket thickness

1.1 mm

 

Max. compressive loading

2000

[N]

Max. Impact loading

10

[Nm ]

Min. bend radius not load

15

[OD]

Min. bend radius load

20

[OD]

Operating temperature range

-20 to +70

[°C]

Storage temperature range

-20 to +70

[°C]

Installation temperature range

-15 to +50

[°C]

Class of fire reaction

Fca

 

  Test standards: EN 60793-1, EN 60794-1-21, EN 60794-1-22, EN 13501-6  

 

Fibre

count

Cable Code

(Ordering Code)

Tube

diameter

Cable outer

diameter

Max. Loading

(Short Term)

Max. Loading

(Long Term)

Cable Weight

(calc.)

2

OPK-U-CTFS-2(1x2,5)LTGH-xx-BK

2,5 mm

5,9 mm

1000 N

400 N

38 kg/km

4

OPK-U-CTFS-4(1x2,5)LTGH-xx-BK

2,5 mm

5,9 mm

1000 N

400 N

38 kg/km

6

OPK-U-CTFS-6(1x2,5)LTGH-xx-BK

2,5 mm

5,9 mm

1000 N

400 N

38 kg/km

8

OPK-U-CTFS-8(1x2,5)LTGH-xx-BK

2,5 mm

5,9 mm

1000 N

400 N

38 kg/km

12

OPK-U-CTFS-12(1x2,5)LTGH-xx-BK

2,5 mm

5,9 mm

1000 N

400 N

38 kg/km

 xx – fiber type (see Cable code datasheet)

Marking Method:  Ink-Jet
Print legend:  OPK –cable type – lot number- length marking per 1 m (customer print legend available on request)
Delivery length: 2000 m ±5% on plywood reel