Outdoor Multitube Cable 72F (SC)
.jpg) 
                    
                Outdoor Multitube Cable 72F (SC)
Rev. 0033-20/23
Full dielectric cable for external installation on cable trays or into duct by pulling
| Fiber count | 72 | 
| Fiber Type | G.652.D, G.657.A1, G.657.A2, G.655, G.656, OM1, OM2, OM2+, OM3, OM4 | 
| Fiber color | Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua | 
| Tube | Gel-Filled PBT buffer tube | 
| Tube color | Blue, Orange, Green, Brown, Grey, White | 
| Tube filling compound | Thixotropic Jelly Compound | 
| Central strength member | FRP rod | 
| Core wrapping | Water-swellable tape | 
| Peripheral strength members | Water-swellable glass yarns | 
| Ripcord | 1x under outer jacket | 
| Outer jacket | UV resistant black HDPE | 
| Jacket thickness | 1.5 mm | 
| Cable outer diameter | 10.2 | [mm] | 
| Tube count | 6 | 
 | 
| Filler count | 0 | 
 | 
| Max. Loading (Short Term) | 2300 | [N] | 
| Max. Loading (Long Term) | 1000 | [N] | 
| Max. compressive loading | 2000 | [N] | 
| Max. Impact loading | 20 | [Nm ] | 
| Min. bend radius not load | 15 | [OD] | 
| Min. bend radius load | 20 | [OD] | 
| Operating temperature range | -40 to +70 | [°C] | 
| Storage temperature range | -40 to +70 | [°C] | 
| Installation temperature range | -15 to +50 | [°C] | 
| Cable Weight (calc.) | 79 | [kg/km] | 
| Class of fire reaction | Fca | 
 | 
| Test standards: EN 60790-1, EN 60794-1-21, EN 60794-1-22, EN 13501-6 | ||
OPK-O-MTFDS-72(6x2.0)LTGP-xx-BK
xx – fiber type (see Cable code datasheet) 
| Marking Method: | Ink-Jet | 
| Print legend: | OPK –cable type – lot number- length marking per 1 m (customer print legend available on request) | 
| Delivery length: | 2100 m, 4200 m ±5% on plywood reel or solid wooden non-returnable drum | 
 
							 
						 
						 
                             
                             
					