OMK-SR-OTS.2 Diagnostic Set

NSN: 6650-16-006-2316
KČM: 0209009700021
Diagnostic set includes measuring instruments and tools for diagnosing faults on fiber optic cables with connectors STRATOS and CTOS, and direct technical successors connectors HMA. The OPTOKON Diagnostic Set includes two instruments - Light source and Power meter. Both instruments are housed in a hard carry case that meets the requirement of fiber optic networks installation and maintenance teams, who require rugged and lightweight fiber optic test equipment that combines high performance with ease of use and reliable operation. The Diagnostic Set allows traceable measurements on dual wavelength and data storage to the PC. It includes the hybrid master HMA-FC patchcord for testing of harsh environmental networks and is comprised of these measurement instruments: LS-800 light source and PM-800 power meter
Material Case Peli 1450:
|
Standard: |
Measuring equipment:
![]() |
LS-800
|
![]() |
PM-800
|
Equipment included in OMK-SR-OTS.2:
Description |
Qty |
Note |
Hard carry case |
1 |
Peli 1450, IP67 |
Measuring instruments: |
1 |
Light source: LS-800V-P2-FC-LED850-30 |
1 |
Power meter: PM-800V |
|
Reference patch cords: FC |
1 |
PC-28OM2-J-002 |
1 |
HMA-J-4xPC-LD4OM2-J-002 |
|
1 |
CTOS-4xPC-LD4OM2-002 |
|
1 |
HMA-J/LD4 OM2-J-002 |
|
Measuring adapter |
1 |
A-FC/PC-02-240-12 |
USB cable |
1 |
Storing data to PC |
Polyethylene bottle with siphon |
1 |
Includes isopropyl alcohol |
Cleaning wipes |
1 |
Cleaning connectors |
External power supply |
1 |
Charging internal battery |
User manuals |
2 |
Light source, Power meter |
Quick start manual |
1 |
Check of the route, Measuring the output of the converter LMC |
- measurement of insertion loss, absolute and relative values
- measurement of two wavelength
- measurement of optical networks during construction and operation
OMK-SR-OTS.2 - Diagnostic Set