Full dielectric cable for external or internal installation on cable trays or into duct by pulling
| Fibre Type | G.652.D, G.657.A1, G.657.A2, G.655, OM1, OM2, OM3, OM4, OM5 |
| Fibre colour | EIA/TIA-598A |
| Tube colour | EIA/TIA-598A |
| Tube | Gel-Filled PBT buffer tube |
| Tube filling compound | Thixotropic Jelly Compound |
| Central strength member | FRP rod (coated if necessary) |
| Peripheral strength members | Water-swellable glass yarns |
| Core wrapping | Water-swellable tape |
| Ripcord | 1x under outer jacket |
| Outer jacket material | UV resistant Thermoplastic FR-LSHF compound according to BS 7878:7 and DIN VDE 0207, part 24, type HM2 |
| Number of fibres | 12 | 24 | 48 | 60 | 72 | 96 | 144 | 192 | 216 | 288 | 432 | |
| Number of fibres in tube | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
| Tube count (layers) | 1 | 2 | 4 | 5 | 6 | 8 | 12 | 16(5+11) | 18(6+12) | 24(9+15) | 36(6+12+18) | |
| Filler count | 4 | 3 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
| Nominal outer diameter (mm) | 11.2 | 11.2 | 11.2 | 11.2 | 12.0 | 13.4 | 16.4 | 15.8 | 16.6 | 18.7 | 21.2 | |
| Outer jacket thickness (mm) | 2.0 | |||||||||||
| Calc. cable weight (kg/km) | 115 | 117 | 122 | 124 | 143 | 175 | 251 | 231 | 255 | 318 | 452 | |
| Short-term tensile strength (N) | 2000 | 2000 | 2000 | 2000 | 3200 | 4100 | 6500 | 3100 | 4200 | 5700 | 4200 | IEC 60794-1-101 |
| Long-term tensile strength (N) | 440 | 440 | 440 | 440 | 900 | 1600 | 4000 | 620 | 1100 | 2600 | 1100 | IEC 60794-1-101 |
| Short-term crush resistance (N/100 mm) | 2000 | IEC 60794-1-103 | ||||||||||
| Long-term crush resistance (N/100 mm) | 600 | IEC 60794-1-103 | ||||||||||
| Max. impact loading (Nm) | 20 | IEC 60794-1-104 | ||||||||||
| Min. bend radius not load (OD) | 15 | IEC 60794-1-111 | ||||||||||
| Min. bend radius load (OD) | 20 | IEC 60794-1-111 | ||||||||||
| Operating temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||||||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||||||||
| Installation temperature range (°C) | -15 to +50 | IEC 60794-1-201 | ||||||||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | ||||||||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 |