All dielectric self-supporting (ADSS) cable for overhead installations.
| Fibre Type | G.652.D, G.657.A1, G.657.A2 |
|---|---|
| Fibre colour | EIA/TIA-598A |
| Tube colour | Natural / White |
| Strength members | Water-swellable Aramid yarn, FRP rod |
| Outer jacket material | UV resistant black HDPE |
| Number of fibres | 2 | 4 | 6 | 8 | 12 | |
|---|---|---|---|---|---|---|
| Number of fibres in tube | 2 | 4 | 6 | 8 | 12 | |
| Tube count (layers) | 1 | 1 | 1 | 1 | 1 | |
| Nominal outer diameter (mm) | 5.1 | 5.1 | 5.1 | 5.1 | 5.1 | |
| Calc. cable weight (kg/km) | 20.5 | 20.5 | 20.5 | 20.5 | 20.5 | |
| Maximum allowable tension (N) | 450 | IEC 60794-1-101 | ||||
| Short-term crush resistance (N/100 mm) | 1000 | IEC 60794-1-103 | ||||
| Max. impact loading (Nm) | 10 | IEC 60794-1-104 | ||||
| Min. bend radius not load (OD) | 15 | IEC 60794-1-111 | ||||
| Min. bend radius load (OD) | 30 | IEC 60794-1-111 | ||||
| Operating temperature range (°C) | -30 to +70 | IEC 60794-1-201 | ||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||
| Installation temperature range (°C) | -15 to +50 | IEC 60794-1-201 | ||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | ||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | ||||
| Recommended clamps | Type AC85F (Manufacturer Telenco) | |||||