Hybrid Copper/Fiber Cable 2-48F + 2.5 mm2 (IC)

Hybrid copper/fiber cable allows to power devices (cameras, sensors, etc.) and at the same time data transmission via optical fibers in one cable.

 

Item Details
Fibre type G.652.D, G.657.A1, G.657.A2, G.655, OM1, OM2, OM3, OM4, OM5
Fibre colour Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua
Tube colour Blue, Orange, Green, Brown
Copper conductor Solid copper wire 2.5 mm², HDPE insulation
Copper conductor colour Black, Red, White, Blue
Central strength member FRP rod (coated if necessary)
Core wrapping Water-swellable tape
Peripheral strength members Water-swellable glass yarns
Ripcord 1× under outer jacket
Outer jacket material UV-resistant black HDPE
Outer jacket thickness 1.5 mm

Parameter 12F / 2C 12F / 4C 24F / 2C 24F / 4C 48F / 2C 48F / 4C Standard
Number of fibres 12 12 24 24 48 48
Number of fibres in tube 12 12 12 12 12 12
Tube count 1 1 2 2 4 4
Copper conductor count 2 4 2 4 2 4
Filler count 2 2 2 2 2 2
Nominal outer diameter (mm) 10.2 12.6 10.2 12.6 12.0 15.0
Calculated cable weight (kg/km) 121 161 123 174 138 210
Short-term tensile strength (N) 2600 2600 3200 3200 5100 5100 IEC 60794-1-101
Long-term tensile strength (N) 1200 1200 1300 1300 1700 1700 IEC 60794-1-101
Crush resistance (N/100 mm) 2000 2000 2000 2000 2000 2000 IEC 60794-1-103
Max. impact loading (Nm) 10 10 10 10 10 10 IEC 60794-1-104
Min. bend radius, no load (OD) 15 15 15 15 15 15 IEC 60794-1-111
Min. bend radius, load (OD) 20 20 20 20 20 20 IEC 60794-1-111
Operating temperature range (°C) −40 to +70 −40 to +70 −40 to +70 −40 to +70 −40 to +70 −40 to +70 IEC 60794-1-201
Storage temperature range (°C) −40 to +70 −40 to +70 −40 to +70 −40 to +70 −40 to +70 −40 to +70 IEC 60794-1-201
Installation temperature range (°C) −15 to +50 −15 to +50 −15 to +50 −15 to +50 −15 to +50 −15 to +50 IEC 60794-1-201
Water tightness (1 m / 24 h) No leakage No leakage No leakage No leakage No leakage No leakage IEC 60794-1-205
Class of fire reaction Fca Fca Fca Fca Fca Fca EN 50575, EN 13501-6
Testing voltage (kV) 2 2 2 2 2 2
Resistance (Ohm/km at 20 °C) 24.5 24.5 24.5 24.5 24.5 24.5

 

Number of fibers Number of conductors Cable code (ordering code) Delivery length Packing
12 2 OPK-O-HCLTS-12(5×2.5)LTGEP+2×2.5mm2-xx-BK 2100 m ± 5%, 4200 m ± 5% Solid wooden drum
12 4 OPK-O-HCLTS-12(8×2.5)LTGEP+4×2.5mm2-xx-BK 2100 m ± 5%, 4200 m ± 5% Solid wooden drum
24 2 OPK-O-HCLTS-24(5×2.5)LTGEP+2×2.5mm2-xx-BK 2100 m ± 5%, 4200 m ± 5% Solid wooden drum
24 4 OPK-O-HCLTS-24(8×2.5)LTGEP+4×2.5mm2-xx-BK 2100 m ± 5%, 4200 m ± 5% Solid wooden drum
48 2 OPK-O-HCLTS-48(6×2.5)LTGEP+2×2.5mm2-xx-BK 2100 m ± 5%, 4200 m ± 5% Solid wooden drum
48 4 OPK-O-HCLTS-48(8×2.5)LTGEP+4×2.5mm2-xx-BK 2100 m ± 5%, 4200 m ± 5% Solid wooden drum

 

OPTOKON ChatBot