FTTx Universal TPU Drop Cable2-12F
| Fibre Type | G.657.A1, G.657.A2, G.657.B3, OM2, OM3, OM4 |
| Fibre colour | EIA/TIA-598A |
| Peripheral strength members | Water-swellable Aramid yarn |
| Outer jacket material | UV resistant, Flame-retardant Thermoplastic Polyurethane |
| Number of fibres | 2 | 4 | 8 | 12 | |
|---|---|---|---|---|---|
| Number of fibres in cable | 2 | 4 | 8 | 12 | |
| Nominal outer diameter (mm) | 2.9 | 3.1 | 3.1 | 3.3 | |
| Calc. cable weight (kg/km) | 6.7 | 7.4 | 7.8 | 8.4 | |
| Outer jacket thickness (mm) | 0.6 | ||||
| Tensile strength (N) | 1000 | IEC 60794-1-101 | |||
| Short-term crush resistance (N/100 mm) | 1000 | IEC 60794-1-103 | |||
| Max. impact loading (Nm) | 2 | IEC 60794-1-104 | |||
| Min. bend radius not load (OD) | 10 | IEC 60794-1-111 | |||
| Min. bend radius load (OD) | 15 | IEC 60794-1-111 | |||
| Operating temperature range (°C) | -20 to +60 | IEC 60794-1-201 | |||
| Storage temperature range (°C) | -30 to +60 | IEC 60794-1-201 | |||
| Installation temperature range (°C) | -5 to +50 | IEC 60794-1-201 | |||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | |||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | |||
| Temperature coefficient (ppm/k) | -2.6 | ||||
| Modulus (GPa) | 77.3 | ||||
| Recommended clamps | Type mini (Manufacturer Telenco) | ||||