Fibre optic cable with full protection against rodents for direct burial installation.
| Fibre Type | G.652.D, G.657.A1, G.657.A2, G.655, OM2, OM3, OM4 |
| Fibre colour | EIA/TIA-598A |
| Tube colour | EIA/TIA-598A |
| Central strength member | FRP rod (coated if necessary) |
| Core wrapping | Water-swellable tape |
| Peripheral strength members | Water-swellable glass yarns |
| Armouring | Corrugated steel tape, longitudinally under jacket |
| Outer jacket material | Black UV resistant halogen-free flame-retardant thermoplastic compound |
| Number of fibres | 12 | 24 | 48 | 60 | 72 | 96 | 144 | |
| Number of fibres in tube | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
| Tube count (layers) | 1 | 2 | 4 | 5 | 6 | 8 | 12 | |
| Filler count | 5 | 4 | 2 | 1 | 0 | 0 | 0 | |
| Nominal outer diameter (mm) | 11.4 | 11.4 | 11.4 | 11.4 | 11.4 | 12.9 | 15.0 | |
| Outer jacket thickness (mm) | 1.5 | |||||||
| Calc. cable weight (kg/km) | 153 | 154 | 156 | 157 | 158 | 195 | 252 | |
| Short-term tensile strength (N) | 3200 | 3200 | 3200 | 3200 | 3200 | 6300 | 5500 | IEC 60794-1-101 |
| Long-term tensile strength (N) | 1020 | 1020 | 1020 | 1020 | 1020 | 2000 | 1750 | IEC 60794-1-101 |
| Short-term crush resistance (N/100 mm) | 3500 | IEC 60794-1-103 | ||||||
| Long-term crush resistance (N/100 mm) | 1050 | IEC 60794-1-103 | ||||||
| Max. impact loading (Nm) | 25 | IEC 60794-1-104 | ||||||
| Min. bend radius not load (OD) | 15 | IEC 60794-1-111 | ||||||
| Min. bend radius load (OD) | 20 | IEC 60794-1-111 | ||||||
| Operating temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||||
| Installation temperature range (°C) | -15 to +50 | IEC 60794-1-201 | ||||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | ||||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | ||||||