Fiber optic cable with full protection against rodents for direct burial installation
| Fibre Type | G.652.D, G.657.A1, G.657.A2, G.655, OM1, OM2, OM3 |
|---|---|
| Fibre colour 1 - 12 | EIA/TIA-598A |
| Tube colour | Natural / White |
| Filling compound | Non-dripping and silicon-free gel |
| Inner peripheral strength members | Water-swellable glass yarns |
| Inner Armouring | Corrugated steel tape, longitudinally under jacket |
| Inner jacket material | UV resistant black PE |
| Outer peripheral strength members | Water-swellable glass yarns |
| Outer Armouring | Corrugated steel tape, longitudinally under jacket |
| Outer jacket material | UV resistant black HDPE |
| Outer jacket thickness | 1.6 mm |
| Number of fibres | 2 | 4 | 6 | 8 | 12 | 16 | 24 | |
|---|---|---|---|---|---|---|---|---|
| Tube count (layers) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
| Tube diameter (mm) | 3.0 | |||||||
| Nominal outer diameter (mm) | 12.4 | |||||||
| Outer jacket thickness (mm) | 1.5 | |||||||
| Calc. cable weight (kg/km) | 174 | 174 | 174 | 174 | 174 | 175 | 175 | |
| Short-term tensile strength (N) | 3000 | IEC 60794-1-101 | ||||||
| Long-term tensile strength (N) | 900 | IEC 60794-1-101 | ||||||
| Short-term crush resistance (N/100 mm) | 5000 | IEC 60794-1-103 | ||||||
| Long-term crush resistance (N/100 mm) | 1500 | |||||||
| Max. impact loading (Nm) | 30 | IEC 60794-1-104 | ||||||
| Min. bend radius not load (mm) | 240 | IEC 60794-1-111 | ||||||
| Min. bend radius load (mm) | 350 | IEC 60794-1-111 | ||||||
| Operating temperature range (°C) | -20 to +70 | IEC 60794-1-201 | ||||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||||
| Installation temperature range (°C) | -5 to +50 | IEC 60794-1-201 | ||||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | ||||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | ||||||