- Abrasion- and cut-resistant for tough handling
- Built for harsh environments
- High tensile strength
- Excellent crush resistance
- Suitable for military data communication
- Wide operating temperature range
- Ready for temporary field deployment
- Glass-yarn layer between jackets for added protection against rodents
Double Jacketed Tactical Cable
Rugged, field-ready cable engineered for harsh conditions. It combines abrasion/cut resistance, high tensile strength, and excellent crush resistance with reliable operation across a wide temperature range. Ideal for military data links, temporary deployments, and sites requiring extra rodent protection thanks to a glass-yarn barrier between the jackets.
| Fibre Type | G.657.A1, G.657.A2, G.657.B3, OM1, OM2, OM3, OM4 |
| Fibre colour | Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua |
| Buffer diameter | 0.9 mm |
| Buffer material | Polyamide |
| Buffers colour | Natural-transparent |
| Strength members | Water-swellable Aramid yarns |
| Inner jacket material | UV resistant, Flame-retardant (V-0, UL94) Thermoplastic Polyurethane |
| Inner jacket thickness | 1.1 mm |
| Inner jacket colour | Black |
| Dialectric armouring | Water-swellable Glass yarns |
| Outer jacket material | UV resistant, Flame-retardant (V-0, UL94) Thermoplastic Polyurethane |
| Outer jacket thickness | 1.2 mm |
| Outer jacket colour | Black |
| Number of fibres | 2 | 4 | 6 | 8 | 12 | |||
| Nominal outer diameter (mm) | 7.9 | 8.1 | 9.1 | 9.6 | 9.9 | |||
| Calc. cable weight (kg/km) | 61 | 64 | 77 | 84 | 89 | |||
| Short-term tensile strength (N) | 3000 | 3000 | 3600 | 3800 | 3800 | IEC 60794-1-101 | ||
| Long-term tensile strength (N) | 960 | 960 | 1150 | 1200 | 1200 | IEC 60794-1-101 | ||
| Crush resistance (N/100 mm) | 5000 | IEC 60794-1-103 | ||||||
| Max. impact loading (Nm) | 20 | IEC 60794-1-104 | ||||||
| Abrasion resistance (10 N load) | 10 000 cycles | IEC 60794-1-102A | ||||||
| Min. bend radius not load (OD) | 10 x OD | IEC 60794-1-111 | ||||||
| Min. bend radius load (OD) | 15 x OD | IEC 60794-1-111 | ||||||
| Operating temperature range (°C) | -40 to +85 | IEC 60794-1-201 | ||||||
| Storage temperature range (°C) | -55 to +85 | IEC 60794-1-201 | ||||||
| Installation temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | ||||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | ||||||
| Number of Fibers | Cable Code (Ordering Code) |
|---|---|
| 2 | OPK-U-DSTTAC-2(2x0.9)N9AAUGU-xx-BK |
| 4 | OPK-U-DSTTAC-4(4x0.9)N9AAUWGU-xx-BK |
| 6 | OPK-U-DSTTAC-6(6x0.9)N9AAUGU-xx-BK |
| 8 | OPK-U-DSTTAC-8(8x0.9)N9AAUGU-xx-BK |
| 12 | OPK-U-DSTTAC-12(12x0.9)N9AAUGU-xx-BK |
xx– fibre type (see Cable code datasheet)