The cable is suitable for aerial use, due to its high crush resistance is also suitable for direct burial installation into sand bed.
| Fibre Type | G.652.D, G.657.A1, OM1, OM2, OM3, OM4 |
| Fibre colour | EIA/TIA-598A |
| Loose Tube | Gel-Filled PBT buffer tube |
| Tube colour | EIA/TIA-598A |
| Filling compound | Low-viscosity filling gel |
| Strength members | FRP rod (coated if necessary) |
| Ripcord | 1x under outer jacket |
| Outer jacket material | UV resistant Black HDPE |
| Number of fibres | 2 | 4 | 6 | 8 | 12 | |
| Number of fibres in tube | 2 | 4 | 6 | 8 | 12 | |
| Tube count (layers) | 1 | 1 | 1 | 1 | 1 | |
| Nominal outer diameter (mm) | 4.3x7.4 | |||||
| Calc. cable weight (kg/km) | 35 | |||||
| Short-term tensile strength (N) | 1600 | IEC 60794-1-101 | ||||
| Long-term tensile strength (N) | 650 | IEC 60794-1-101 | ||||
| Short-term crush resistance (N/100 mm) | 4000 | IEC 60794-1-103 | ||||
| Max. impact loading (Nm) | 10 | IEC 60794-1-104 | ||||
| Min. bend radius not load (OD) | 150 | IEC 60794-1-111 | ||||
| Min. bend radius load (OD) | 250 | IEC 60794-1-111 | ||||
| Operating temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | ||||
| Installation temperature range (°C) | -15 to +50 | IEC 60794-1-201 | ||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | ||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | ||||
| Recommended clamps | Type ODWAC (Manufacturer Telenco) | |||||