Full dielectric cable for external installation on cable trays or into duct
| Fibre Type | G.652.D, G.657.A1, G.657.A2, G.655, OM1, OM2, OM3, OM4 |
| Fibre colour | EIA/TIA-598A |
| Tube colour | EIA/TIA-598A |
| Tube | Gel-filled PBT buffer tube |
| Tube filling compound | Low-viscosity filling gel |
| Central strength member | FRP rod (coated if necessary) |
| Core wrapping | Water-swellable tape |
| Ripcord | 1× under outer jacket |
| Outer jacket material | UV resistant black MDPE |
| Number of fibres | 144 | 192 | 288 | 432 | 576 | 864 | |
| Number of fibres in tube | 24 | 24 | 24 | 24 | 24 | 24 | |
| Tube count (layers) | 6 | 8 | 12 | 18 (6+12) | 24 (9+15) | 36 (6+12+18) | |
| Filler count | 0 | ||||||
| Nominal outer diameter (mm) | 11.3 | 12.9 | 16.2 | 16.5 | 18.9 | 21.7 | |
| Outer jacket thickness (mm) | 1.5 | ||||||
| Calc. cable weight (kg/km) | 99 | 129 | 203 | 207 | 276 | 359 | |
| Short-term tensile strength (N) | 2500 | 2500 | 2500 | 2500 | 2500 | 2500 | IEC 60794-1-101 |
| Long-term tensile strength (N) | 1050 | 1050 | 1050 | 1050 | 1050 | 1050 | IEC 60794-1-101 |
| Short-term crush resistance (N/100 mm) | 1000 | IEC 60794-1-103 | |||||
| Long-term crush resistance (N/100 mm) | 300 | IEC 60794-1-103 | |||||
| Max. impact loading (Nm) | 5 | IEC 60794-1-104 | |||||
| Min. bend radius not load (OD) | 15 | IEC 60794-1-111 | |||||
| Min. bend radius load (OD) | 20 | IEC 60794-1-111 | |||||
| Operating temperature range (°C) | -40 to +70 | IEC 60794-1-201 | |||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | |||||
| Installation temperature range (°C) | -15 to +50 | IEC 60794-1-201 | |||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | |||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 |