Multitube micro cable for external installation by air-blowing technique
| Fibre Type | G.652.D, G.657.A1, G.657.A2, OM1, OM2, OM3, OM4 |
|---|---|
| Fibre colour | EIA/TIA-598A |
| Tube colour 1-12 | EIA/TIA-598A |
| Central strength member | FRP rod (coated if necessary) |
| Ripcord | 1x under outer jacket |
| Outer jacket material | UV resistant black HDPE |
| Outer jacket thickness | 0.5 mm |
| Number of fibres | 12 | 24 | 36 | 48 | 60 | 72 | 96 | 144 | 192 | 216 | 288 | 432 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of fibres in tube | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
| Tube count (layers) | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 12 | 5+11 | 6+12 | 9+15 | 6+12+18 | |
| Filler count | 4 | 3 | 2 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
| Nominal outer diameter (mm) | 5.1 | 5.1 | 5.1 | 5.1 | 5.1 | 5.7 | 6.5 | 8.6 | 8.3 | 8.7 | 10.0 | 11.7 | |
| Calc. cable weight (kg/km) | 23 | 23 | 23 | 23 | 23 | 26 | 39 | 63 | 54 | 61 | 88 | 111 | |
| Short-term tensile strength (N) | 750 | 750 | 750 | 750 | 750 | 930 | 1800 | 2800 | 750 | 930 | 2900 | 930 | IEC 60794-1-101 |
| Long-term tensile strength (N) | 460 | 460 | 460 | 460 | 460 | 550 | 1100 | 2000 | 460 | 550 | 1800 | 550 | IEC 60794-1-101 |
| Short-term crush resistance (N/100 mm) | 700 | IEC 60794-1-103 | |||||||||||
| Long-term crush resistance (N/100 mm) | 200 | IEC 60794-1-103 | |||||||||||
| Max. impact loading (Nm) | 3 | IEC 60794-1-104 | |||||||||||
| Min. bend radius not load (OD) | 10 | IEC 60794-1-111 | |||||||||||
| Min. bend radius load (OD) | 20 | IEC 60794-1-111 | |||||||||||
| Operating temperature range (°C) | -30 to +70 | IEC 60794-1-201 | |||||||||||
| Storage temperature range (°C) | -40 to +70 | IEC 60794-1-201 | |||||||||||
| Installation temperature range (°C) | -15 to +50 | IEC 60794-1-201 | |||||||||||
| Water tightness (1 m / 24 hrs.) | No leakage | IEC 60794-1-205 | |||||||||||
| Class of fire reaction | Fca | EN 50575, EN 13501-6 | |||||||||||